Functions and
Technical specification |
|
|
|
|
Measurement
functions |
Colorimetry |
CIEL*a*b*, CIE*C*h(a*b*),r E*CIELAB |
CIE XYZ,CIE xyY;CIE L*u*v*,
CIE L*C*h(u*v*),rE CIELUV ;
LABmg,LCHmg,rEmg;Hunter
Lab,rE Hunter Lab;RxRyRz |
| Special color deviation formulas |
rE*2000, rE*94,
rE CMC,rE FMCII |
Metamerism |
| Densitometry |
Density, Dot gain, Dot area, Trapping |
All densities,Printing plate,Print
characteristic,Contrast,Greyness,
Hue error,Auto Function |
| Spectrum |
Reflection spectrum |
Density spectrum |
| Dye Strength |
optional |
Absolute(K/S) and relative(K/S) |
| White- and Yellowness |
optional |
Whiteness CIE,
Whiteness ASTM E313,
Whiteness Berger ,
Whiteness Stensby,
ISO Brightness R457,
Yellowness ASTM E313,
Yellowness ASTM D1925,
Tint CIE |
| Special functions |
Best Match |
|
| Color guides |
optional |
| PANTONE |
® |
Color Formula |
Guide;TOYO Color Finder;
DIC Color Guide;HKS E,K,N and
Z |
|
| Security |
optional |
Setting protection, Multi user |
Measurement
conditions |
White base |
Absolute, relative |
Specification subject to change
without notice |
IIIumination
types |
D50,D65,A,C,D30...D300,F1...F12,
User defined |
Standard
observers |
2°, 10° |
Density
standards |
ISO Status A,ISO Status E,ISO Status I,
ISO Status T,DIN 16536,DIN 16536 NB,
SPI |
Measurement
technology |
Spectral analysis |
Holographic difraction grating |
| Spectral range |
380nm to 730nm |
Physical
resolution |
10nm(internal resolution: 3.3nm) |
Measurement
modes |
Reflection |
Measurement
geometry |
45°/0° ring optic, DIN 5033 |
Measurement
aperture |
4.5mm |
| Light souce |
Gas-filled tungsten,type A illumination |
| Physical filters |
- Neutral, incandescent lamp light
- Polarized
- Approximated daylight D65
- On request UV cutoff |
Measurement
time |
Approximately 1.5 sec |
Measurement
range |
Density DIN 16536: 0.0D - 2.5D |
Interinstrument
agreement |
Typical 0.3 rE* CIELAB,
or 0.15 rE CMC(2:1) ,average based
on 12 BCRA tiles(D50.2°) |
| Linearity |
±0.01D |
Short-term
repeatability |
0.02rE*CIELAB (D50.2°) ,mean value
of 10 measurements every 10 sec on
white |
| Density repeatability |
Density DIN 16536(Repeatability±0.01D)
No Filter 0.0D-2.5D,Yellow 0.0D-2.0D
Pol Filter 0.0D-2.2D,Yellow0.0D-1.8D |
Measurement
head |
Extendable |
| Filter wheel |
Electronic selection of filter |
White
calibration |
Automatic on integrated white tile |
Instrument
check |
Automatic check of the spectral
calibration |
Density filter
recognition |
Manual and automatic |
| Average |
Averaging for multiple measurement
values |
| Color detection |
Manual and automatic assignment of
samples to references |
| Data interface |
Data interface
connector |
RJ45 connector |
Serial data
interface |
RS232C with Baud rate: 300 to 57,600 |
| Ethernet |
10 BaseT, 10Mbps |
| Power supply |
Power supply |
NiMH battery pack, nom. 7.2V,1300mAh |
AC adapter
requirements |
85 VAC to 270 VAC, 47 Hz to 63 Hz |
| Charge time |
Approximately 3 hours,
automatic disconnection |
| Charge status |
Automatic capacity checking and display |
Measurements
per charge |
Approximately 3000 |
Mechanical
data |
Physical
dimensions |
24.5 cm lenth,8.3 cm width,8 cm height
(9.6 in lenth, 3.3 in width, 3.2 in height) |
| Weight |
Approximately 990 g, (2.18 lb) |